Time Narration
00:01 Welcome to this tutorial on simulating an Equilibrium Reactor in DWSIM.
00:07 In this tutorial, we will learn to:
00:10 Define an Equilibrium Reaction
00:13 Simulate an Equilibrium Reactor
00:16 Calculate Conversion percentage and Reaction Extent
00:20 To record this tutorial, I am using
00:23 DWSIM 5.2 (Classic UI) update 22 and Windows 10
00:30 The process demonstrated in this tutorial is identical in other OS also such as-

Linux, Mac OS X or FOSSEE OS on ARM.

00:41 To practice this tutorial, you should know to-

Add components to a flowsheet.

00:47 select thermodynamic packages.
00:50 add material and energy streams and specify their properties.
00:56 The prerequisite tutorials are mentioned on our website.
01:01 You can access these tutorials and all the associated files from this site.
01:07 We will develop a flowsheet to determine the exit composition from an Equilibrium Reactor.
01:14 Here we give Reaction and Inlet Stream Conditions.
01:19 Here we give Property Package and Reaction Temperature.
01:24 I have already opened DWSIM on my machine.
01:28 Go to File menu and select New Steady-state Simulation.
01:35 Simulation Configuration Wizard window appears.
01:39 Click on Next button at the bottom.
01:43 In the Compounds search tab, type Carbon monoxide.
01:48 Select Carbon monoxide from the ChemSep database.
01:52 Similarly, add Water.
01:56 Similarly, add Hydrogen.
02:00 Next, add Carbon Dioxide.
02:04 And then at the bottom, click on the Next button.
02:09 The Property Packages opens.
02:12 From Available Property Packages list, double-click on Raoult’s Law.
02:18 Then click on the Next button.
02:22 We will be moved to a new window named Flash Algorithm.
02:27 From Default Flash Algorithm, select Nested Loops(VLE).
02:33 Click on the Next button.
02:36 The next option is System of Units.
02:40 Under System of Units, we will select C5.
02:46 Then at the bottom, click on the Finish button.
02:51 Let us now maximize the simulation window.
02:55 Now let’s insert a feed stream that enters the Equilibrium Reactor.
03:00 On the right hand side of the main simulation window, go to Flowsheet Objects.
03:06 In the Filter List tab, type Material Stream.
03:11 From the displayed list, drag and drop a Material Stream to the Flowsheet.
03:17 Let’s change the name of this stream to Feed.
03:21 Now we will specify the Feed stream properties.
03:26 Go to Input Data.
03:29 Under Stream Conditions tab, select Flash Spec as Temperature and Pressure (TP), if not already selected.
03:38 By default, Temperature and Pressure are already selected as Flash Spec.
03:44 Change Temperature to 25 degree Centigrade and press Enter.
03:40 Change Pressure to 1.01325 bar and press Enter.
03:58 Change Mass Flow to 3600 kg per hour and press Enter.
04:05 Now let us specify the feed stream compositions.
04:10 Under Input Data, click on Compound Amounts tab.
04:15 Choose the Basis as Mole Fractions, if not already selected.
04:20 By default, Mole Fractions is selected as Basis.
04:25 Now for Carbon monoxide, enter the Amount as 0.5 and press Enter.
04:33 For Water, type 0.5 and press Enter.
04:38 For Hydrogen, type 0 and press Enter.
04:43 Similarly, for Carbon dioxide, type 0 and press Enter.
04:50 At the bottom, click on Commit New Values button.
04:56 Next, we will define the Equilibrium Reaction.
04:59 Under Tools, click on Reactions Manager.
05:04 Chemical Reactions Manager window opens.
05:08 Under Chemical Reactions tab, click on the green coloured Add Reaction button.
05:15 Then click on Equilibrium.
05:18 Add New Equilibrium Reaction window opens.
05:22 Under Identification, enter the Name as Water Gas Shift Reaction.
05:29 Let’s enter the Description.

Reaction of carbon monoxide and water vapor to form carbon dioxide and hydrogen.”

05:40 Next part is the table of Components and Stoichiometry.
05:45 The first column Name shows the available components here.
05:50 The second column corresponds to its Molar Weight.
05:54 The next column is Include. Under Include, check all the check boxes.
06:02 The fourth column is BC. Under BC, check the Carbon monoxide check box as conversion is defined in terms of Carbon monoxide.
06:14 Next column is Stoichiometric Coefficients
06:18 Under Stoichiometric Coefficients column, enter:

-1 for Carbon monoxide

06:25 -1 for Water
06:28 1 for Hydrogen and
06:31 1 for Carbon dioxide

Then press Enter.

06:36 In the Stoichiometry field, we can see it shows OK.
06:41 It means the reaction is balanced after entering the stoichiometric coefficients.
06:47 Here the Equation field shows the reaction equation.
06:51 Then comes Equilibrium Reactions Parameters.
06:55 The Basis is already selected as fugacity.
06:59 Select Phase as Vapor.
07:03 Now, go to Equilibrium Constant .
07:07 In an Equilibrium Reaction, the equilibrium constant can be defined in three different ways.
07:14 First is Gibbs Energy of Reaction.
07:18 If the equilibrium constant is unknown, it is calculated directly from Gibbs energy of reaction.
07:25 Second is T function.
07:28 Here the equilibrium constant can be defined as a function of temperature.

It is in the form of ln Keq f of T.

07:39 Third is Constant value where the equilibrium constant is defined directly.
07:45 Here, we don't know the equilibrium constant directly or as a function of temperature.
07:52 So, we will let it calculate from the Gibbs energy of reaction.

Select Calculate from Gibbs Energy of Reaction.

08:02 Click on OK at the bottom.

And then close the Chemical Reactions Manager window.

08:09 Now let us insert an Equilibrium Reactor to the flowsheet.
08:14 Go to Flowsheet Objects.
08:17 In the Filter List tab, type Equilibrium Reactor.
08:22 Drag and drop Equilibrium Reactor to the flowsheet.
08:26 Let us arrange it as required.
08:29 Next, name the reactor as Equilibrium Reactor.
08:34 Now let’s insert two more material streams that exit the Equilibrium Reactor.
08:41 To do that, let us drag one Material Stream to the flowsheet.
08:47 Let us now arrange it.
08:50 We will leave that stream as unspecified.
08:54 Then we will change the name of this stream to Vapour Product.
09:00 Next, we will insert another Material Stream.
09:04 Let us once again arrange it.
09:07 Leave that stream as unspecified.
09:10 And name this stream as Liquid Product.
09:14 Next, we will insert one Energy Stream.
09:20 And name this stream as Energy.
09:24 We are now ready to specify the Equilibrium Reactor.

So let’s click on it.

09:31 On the left, we can see a tab displaying properties related to the Equilibrium Reactor.
09:38 Under Connections, click on the drop-down against Inlet Stream.

And select Feed.

09:46 Next, click on the drop-down against Outlet Stream 1 and select Vapour Product.
09:54 Next, click on the drop-down against Outlet Stream 2 and select Liquid Product.
10:02 Next click on the drop-down against Energy Stream and select Energy.
10:10 Now we will go to the next section, Calculation Parameters.
10:16 Here, the first option is Reaction Set.
10:21 This option is selected as Default Set.
10:25 Next, click on the drop-down against Calculation Mode.
10:30 Select Define Outlet Temperature.
10:34 Enter 225 degree C against Outlet Temperature.
10:40 Now we will run the simulation.
10:43 So, click on Solve Flowsheet button on the toolbar.
10:48 Once the calculation are complete, click on the Equilibrium Reactor in the flowsheet.
10:54 Go to the Property Editor Window of the Equilibrium Reactor.

Locate Results section.

11:02 Under Reactions tab, check Extent.

It is 20.043.

11:08 This is the extent of the water gas shift reaction at 225 degree Centigrade.
11:14 Now go to the Conversions tab.
11:17 We will look into the individual conversions of all the reactants.
11:22 Here for Carbon monoxide, the conversion is 92.2478% and for Water it is 92.2478%.
11:34 Now, go to Insert menu and select Master Property Table.
11:40 Double-click on the Master Property Table.
11:44 Configure Master Property Table window opens.
11:48 Enter Name as Stream Wise Results Equilibrium Reactor.
11:54 Enter Object Type as Material Stream.
11:58 By default, Material Stream is already selected.

So we will not change it.

12:04 Under Properties to display, select Object as Feed, Vapour Product and Liquid Product.
12:14 Under Property, scroll down to see all the parameters.
12:20 Now select the properties as

Temperature, Pressure, Mass Flow , Molar Flow

12:32 Molar Flow (Mixture) / Carbon monoxide
12:36 Mass Flow (Mixture) / Carbon monoxide
12:40 Molar Flow (Mixture) / Water
12:43 Mass Flow (Mixture) / Water
12:46 Molar Flow (Mixture) / Hydrogen
12:49 Mass Flow (Mixture) / Hydrogen
12:54 Molar Flow (Mixture) / Carbon dioxide
12:57 Mass Flow (Mixture) / Carbon dioxide
13:01 Let’s close this window.
13:04 Move the Master Property Table for better visibility.
13:10 Here we can see the corresponding results for Vapour Product, Liquid Product and Feed.
13:17 The reaction is a Vapour Phase reaction.
13:21 So, we can see that Liquid Product stream shows zero flow rate and composition.
13:28 Let's summarize.
13:30 In this tutorial, we have learnt to

Define an Equilibrium Reaction, Simulate an Equilibrium Reactor, Calculate Conversion percentage and Reaction extent

13:42 As an assignment,

Repeat this simulation with different compounds and thermodynamics.

13:48 Different feed conditions

Different Calculation Parameters

13:53 Watch the video available at the following link.

It summarizes the Spoken Tutorial project.

14:00 The Spoken Tutorial Project Team

Conducts workshops and Gives certificates.

14:06 For more details, please write to us.
14:10 Please post your times queries in this forum.
14:14 The FOSSEE team coordinates conversion of existing flow sheets into DWSIM.
14:20 We give honorarium and certificates.

For more details, please visit this site.

14:26 The FOSSEE team coordinates coding of solved examples of popular books.
14:32 We give honorarium and certificates.

For more details, please visit this site.

14:39 The FOSSEE team helps migrate commercial simulator labs to DWSIM.
14:45 We give honorarium and certificates.

For more details, please visit this site.

14:52 Spoken Tutorial and FOSSEE projects are funded by NMEICT, MHRD, Government of India.
15:01 This tutorial is contributed by Kaushik Datta and Priyam Nayak.

Thanks for joining.