Osdag/C3/Handling-unsafe-designs-in-Osdag/English
From Script | Spoken-Tutorial
Title of the script: Handling unsafe designs in Osdag
Author: Monika Soni (script), Anandajith TS (recording)
Keywords: Video tutorial, Unsafe Design, Log Messages, Error, Warning, Info, Osdag
Visual Cue | Narration |
Slide: Title Slide | Welcome to the spoken tutorial on ‘Handling unsafe designs in Osdag’. |
Slide: Learning Objectives | In this tutorial, we will learn how to
|
Slide: System Requirements | To record this tutorial, I am using
|
Slide: Pre-requisites
|
To follow this tutorial you should have,
The prerequisite tutorials are available on this website. |
Only narration | The user interface of Osdag for Ubuntu Linux, and for Windows is the same.
|
Point to the home page of the Tension Member Design >> Select Bolted to End Gusset module | Let us switch to the home page of Tension Member Design.
Select Bolted to End Gusset module. |
Point toward the Input Dock fields | I have loaded the Logs underscore sample underscore design dot OSI file. |
Only narration | Please pause the tutorial and load the input file. |
Click on the Design button | Click on the Design button below to perform the design. |
Only narration | Osdag carries out the design. |
Point toward the CAD window | Note that the CAD window is inactive. |
Point toward the Output Dock | The Output Dock is not populated with the output values. |
Only narration | This is because the design is complete but unsafe. |
Point to the Output Dock. |
Let us disable the Output Dock to maximise the log messages window. |
Click on the close Output Dock button | Click on the close button at the top right corner of the Output Dock. |
Point toward the Log messages | We see the colour-coded log messages pertaining to the design. |
Highlight the timestamp in the log messages | The log messages are marked with a timestamp for the reference of the users. |
Highlight ERROR message | The ERROR message is marked in red and indicates the status of the design.
|
Only narration | Let us rectify the design using the log messages and arrive at a safe design solution. |
Point to the message in blue colour. |
The WARNING messages are marked in Blue colour. |
Highlight the WARNING message | The WARNING message gives a warning pertaining to a specific design check. |
Highlight the WARNING message | The WARNING message reads, that the tension force exceeds the tension capacity. . |
Point to the message. |
This means that the force exceeds the member capacity in tension. |
Point to the message. | The INFO messages are marked in Green colour. |
Highlight the first INFO message | The INFO message gives suggestions to rectify the unsafe design. |
Highlight the last INFO message | It also suggests where the design check or a trial design has ended. |
Highlight the first INFO message | The INFO message reads, ‘Define member(s) with a higher cross sectional area.’ |
Highlight 80 x 80 x 8 in the message. |
This means we have to define a section with an area greater than 80 x 80 x 8. |
Only narration | Let us define a new section. |
Click on the Section Size drop-down menu | Click on the Section Size drop-down menu and select Customized. |
Double-click on 80 x 80 x 8 in the Selected list | Double-click on 80 x 80 x 8 in the Selected list to deselect the section. |
Scroll down in the Available list and double click on 90 x 90 x 8 | Now, scroll down in the Available list.
|
Click on the Submit button | Click on the Submit button below to confirm and exit. |
Click on the Design button | Then, click on the Design button below to perform the design. |
Point to the messages. | We see ERROR and WARNING messages again, as the design is still unsafe. |
Highlight the WARNING message | The WARNING message reads, that the tension force exceeds the tension capacity. |
Point to the messages. |
Here, the section area is satisfied but the plate thickness is less. |
Only narration | Let us define a thicker gusset plate. |
Click on the Thickness drop-down menu | Click on the Thickness drop-down menu and select Customized. |
Double-click on 12 in the Selected list | Double-click on 12 in the Selected list to deselect the plate. |
From the Available list double-click on 16 | Now, from the Available list double-click on 16 to select the plate. |
Click on the Submit button | Click on the Submit button below to confirm and exit. |
Click on the Design button | Again, click on the Design button below to perform the design. |
Only narration | Osdag carries out the design. |
Highlight the fourth INFO message | The INFO message reads, ‘Overall bolted tension member design is safe.’. |
Only narration | This means that the design is complete and successful. |
Highlight the third INFO message | If there is scope to optimize the design, Osdag will display additional INFO messages. |
Only narration | But, this does not mean that the design is unsafe. |
Only narration | Optimum design can be achieved by defining more inputs for the section, connectors, etc. |
Only narration | This brings us to the end of this tutorial.
|
Slide: Summary
|
In this tutorial, we have
|
Slide: Assignment | As an assignment, do the following
|
Slide: About Spoken Tutorial Project | The video at the following link summarizes the Spoken Tutorial Project
|
Slide:Spoken Tutorial Workshops | The Spoken Tutorial Project team conducts workshops and gives certificates
|
Slide:Answers for THIS Spoken Tutorial | Please post your timed queries in this forum |
Slide: FOSSEE Forum | For any general or technical questions on Osdag, visit the FOSSEE forum and post your question |
Slide: Sample Design Examples
|
|
Slide: Acknowledgement | The Spoken Tutorial project is funded by the Ministry of Education, Government of India |
Slide: Thank you | This is Anandajith TS, IIT Bombay signing off
|