Difference between revisions of "ChemCollective-Virtual-Labs/C2/Solution-Transfer-Modes-in-VLabs/English"
Snehalathak (Talk | contribs) (Created page with " '''Title of script''': '''Solution Transfer Modes in Vlabs''' '''Author: Dr.Snehalatha Kaliappan''' '''Keywords: '''Chemistry Virtual labs, workbench, stockroom, Precise...") |
|||
| Line 1: | Line 1: | ||
'''Title of script''': '''Solution Transfer Modes in Vlabs''' | '''Title of script''': '''Solution Transfer Modes in Vlabs''' | ||
| − | |||
'''Author: Dr.Snehalatha Kaliappan''' | '''Author: Dr.Snehalatha Kaliappan''' | ||
| − | |||
'''Keywords: '''Chemistry Virtual labs, workbench, stockroom, Precise transfer, Realistic transfer, Significant transfer, video tutorial. | '''Keywords: '''Chemistry Virtual labs, workbench, stockroom, Precise transfer, Realistic transfer, Significant transfer, video tutorial. | ||
| Line 71: | Line 69: | ||
Point to '''Resources Type''': '''Virtual Labs'''. | Point to '''Resources Type''': '''Virtual Labs'''. | ||
| − | ||By default the main page opens with ''' | + | ||By default the main page opens with '''Resource Type''': '''Virtual Labs'''. |
List of available topics are listed on the page. | List of available topics are listed on the page. | ||
| Line 107: | Line 105: | ||
Point to the information | Point to the information | ||
| − | ||From the '''Solutions tab''', click on '''1 Molar Glucose Solution | + | ||From the '''Solutions tab''', click on '''1 Molar Glucose Solution'''. |
Revision as of 16:15, 28 April 2025
Title of script: Solution Transfer Modes in Vlabs
Author: Dr.Snehalatha Kaliappan
Keywords: Chemistry Virtual labs, workbench, stockroom, Precise transfer, Realistic transfer, Significant transfer, video tutorial.
| Visual Cue | Narration |
|---|---|
| Slide Number 1
Title Slide |
Welcome to this spoken tutorial on Solution Transfer Modes in Vlabs. |
| Slide Number 2
|
In this tutorial, we will learn about,
3 different modes of solution transfer in Vlabs Precise transfer Significant transfer and Realistic transfer |
| Slide Number 3
System Requirement |
Here I am using,
Ubuntu Linux OS version 22.04 ChemCollective Virtual labs version 2.1.0 Java version 11.0.5 and A working internet connection |
| Slide Number 4
Prerequisite |
To follow this tutorial,
|
| Type ChemCollective virtual labs on Google search page. | For this demonstration I will open the ChemCollective Virtual Labs online interface.
Open any web browser. In the Google search, type ChemCollective virtual labs and press Enter. |
| https://chemcollective.org/vlabs | Click on the ChemCollective Virtual labs link that appears first on the page. |
| Cursor on the page.
Point to Resources Type: Virtual Labs. |
By default the main page opens with Resource Type: Virtual Labs.
List of available topics are listed on the page. |
| Click on Stoichiometry topic. | Click on the down arrow next to Stoichiometry topic.
A menu with the available virtual lab experiments opens. |
| Click on the yellow coloured Go button.
Cursor on the page. |
In the Glucose Dilution Problem activity, click on the Go button.
|
| Point to Stockroom and Workbench 1. | Page has two panels: Stockroom and Workbench 1. |
| Point to the Solutions, Glassware and Tools tabs. | In the Stockroom, we have Solutions, Glassware and Tools tabs.
|
| From the Stockroom, click on 1M Glucose Solution.
Point to the information |
From the Solutions tab, click on 1 Molar Glucose Solution.
|
| From the Stockroom, click on the Glassware tab.
Click on Erlenmeyers.
|
From the Stockroom, click on Glassware tab.
|
| Drag the Glucose solution flask to the empty flask | I want to transfer 1 Molar Glucose solution to an empty flask.
Drag the Glucose solution flask to the empty receiving flask. |
| Cursor on the pop-up window. | A pop-up window with 3 different modes of transfer appears. |
| Slide Number 5
Precise Transfer |
Precise transfer mode is used to transfer precisely upto second decimal point.
|
| Type 10.546 in the volume field. Click the on Pour button. | I will transfer 10.546 mL of solution.
Type 10.546 in the volume field. Click on the Pour button. |
| Click on the X button on the right-side of the pop-up window. | Click on the X button on the right-side of the pop-up window to close the window. |
| Click on the receiving flask.
|
Click on the receiving flask.
The left panel shows the volume in the flask as 10.546 ml. |
| Right-click on the flask.
|
Let us empty the liquid in the receiving flask.
The flask is now empty. |
| Cursor on the workbench. | Now I will demonstrate Significant Transfer mode.
|
| Slide Number 6
Significant Transfer |
Significant transfer is used to transfer liquids from or to the glassware which hold a definite volume of liquid.
|
| Click on the 10 ml Pipette from Glassware tab. | I will select a 10 ml pipette from the Glassware tab on the left panel. |
| Drag the 10 ml pipette to the Glucose stock solution flask. | Drag the 10 mL pipette to the Glucose stock solution flask. |
| Cursor on the pop-up window.
Click on the Sig Fig button. |
The pop-up transfer window appears.
Click on the Sig Fig button. Notice the Withdraw and Pour buttons. |
| Type 10.00 in the volume field. click on Withdraw button.
|
Since we are using a 10 ml pipette, type 10.00 in the volume field.
Click on the Withdraw button.
|
| drag the pipette to the receiving flask. | Now drag the pipette to the receiving flask.
|
| Type 10 and now click on the Pour button. | Type 10 and now click on the Pour button.
Notice the error message in the pop-up window. |
| Type 10.00 and click on the Pour button. | While pouring, we need to type the decimal figures also.
So type 10.00 and click the Pour button. Close the pop-up window. |
| Cursor on the receiving flask, | Now you can see 10 ml is transferred to the receiving flask. |
| Right-click on the Pipette and select remove. | To delete the pipette, right-click on the pipette and select Remove option. |
| Right-click on the flask.
Click on the Remove liquid option. |
Again empty the liquid in the receiving flask.
Right-click on the flask, click on Remove Liquid option.
|
| Slide Number 7
Realistic Transfer |
In realistic transfer mode, solutions are transferred by holding down the Pour button.
The longer the Pour button is held down the greater volume of solution is transferred. |
| Drag the flask with Glucose solution on to the empty erlenmeyer flask.
In the transfer pop-up choose the Realistic option. |
Bring the flask with Glucose solution on to the empty Erlenmeyer flask.
In the transfer pop-up choose the Realistic option. |
| Text Annotation.
|
Press and hold the, Hold to Pour button to transfer the solution.
|
| Cursor on the pop-up window. | The amount of solution transferred is shown in the pop-up window. |
| Click on the X button to close the window. | Close the pop-up window. |
| Slide Number 8
Summary In this tutorial, we have learned about 3 different modes of transfer in Vlabs.
Realistic transfer Significant transfer |
With this we come to the end of this tutorial.
|
| Slide Number 9
Assignment |
As an assignment,
Practice the transfer of solutions using various transfer modes demonstrated in the tutorial. |
| Thank you. |