Line 13: | Line 13: | ||
|- | |- | ||
| 00:10 | | 00:10 | ||
− | | In this spoken tutorial, we will learn: | + | | In this spoken tutorial, we will learn: to set up '''serial''' communication between '''Scilab''' and '''SBHS''' |
|- | |- | ||
| 00:17 | | 00:17 | ||
− | | | + | |to perform a '''Step Test''' experiment. |
|- | |- | ||
| 00:20 | | 00:20 | ||
− | | For this tutorial, I am using '''Windows-7''' | + | | For this tutorial, I am using '''Windows-7 Operating System''' and '''Scilab''' 5.3.3. |
|- | |- | ||
| 00:28 | | 00:28 | ||
− | | You may download | + | | You may download Scilab from '''www.scilab.org'''. |
|- | |- | ||
Line 49: | Line 49: | ||
|- | |- | ||
| 01:19 | | 01:19 | ||
− | | Download the file available under the section '''SBHS Local Code''' and save this file on the | + | | Download the file available under the section '''SBHS Local Code''' and save this file on the Desktop. |
|- | |- | ||
Line 57: | Line 57: | ||
|- | |- | ||
| 01:34 | | 01:34 | ||
− | | Right-click on | + | | Right-click on this file and choose '''Extract here.''' |
|- | |- | ||
Line 77: | Line 77: | ||
|- | |- | ||
| 01:58 | | 01:58 | ||
− | | To do this, right click on '''My Computer '''and then click on '''Properties'''. | + | | To do this, right-click on '''My Computer '''and then click on '''Properties'''. |
|- | |- | ||
Line 97: | Line 97: | ||
|- | |- | ||
| 02:33 | | 02:33 | ||
− | |Locate the ''' | + | |Locate the '''Ports (COM & LPT)''' option. |
|- | |- | ||
Line 117: | Line 117: | ||
|- | |- | ||
| 03:03 | | 03:03 | ||
− | | Note down the appropriate '''COM''' number | + | | Note down the appropriate '''COM''' number; in my case it is '''COM14.''' |
|- | |- | ||
Line 145: | Line 145: | ||
|- | |- | ||
| 03:40 | | 03:40 | ||
− | | In the '''COM port number''' | + | | In the '''COM port number''' drop-down menu, choose the port number to any other single-digit number. |
|- | |- | ||
Line 153: | Line 153: | ||
|- | |- | ||
| 03:55 | | 03:55 | ||
− | | Hence | + | | Hence you can forcibly use a particular '''COM''' port number, if there is no other '''USB''' device connected. |
|- | |- | ||
Line 173: | Line 173: | ||
|- | |- | ||
| 04:23 | | 04:23 | ||
− | | Open the '''Scilab local codes '''folder that we saved on the Desktop. | + | | Open the '''Scilab local codes '''folder that we have saved on the Desktop. |
|- | |- | ||
Line 189: | Line 189: | ||
|- | |- | ||
| 04:43 | | 04:43 | ||
− | | If it doesn't open the file, click on '''File''' menu, then on '''Open a file.''' | + | | If it doesn't open the file, click on the '''File''' menu, then on '''Open a file.''' |
|- | |- | ||
Line 197: | Line 197: | ||
|- | |- | ||
| 04:57 | | 04:57 | ||
− | | Switch to the '''scilab workspace''' and execute the following commands. | + | | Switch to the '''scilab workspace''' and '''execute''' the following commands. |
|- | |- | ||
| 05:03 | | 05:03 | ||
− | | Type: '''get d space dot dot slash common underscore files '''and press '''Enter''' key. | + | | Type: '''get d space dot dot slash common underscore files '''and press the '''Enter''' key. |
|- | |- | ||
Line 257: | Line 257: | ||
|- | |- | ||
| 06:21 | | 06:21 | ||
− | | Let me switch to slides. | + | | Let me switch to the slides. |
|- | |- | ||
Line 305: | Line 305: | ||
|- | |- | ||
| 07:35 | | 07:35 | ||
− | | The first graph is of '''Heater in percentage | + | | The first graph is of '''Heater in percentage''', |
|- | |- | ||
| 07:40 | | 07:40 | ||
− | | | + | | the second graph is of '''Fan in percentage''' and |
|- | |- | ||
| 07:44 | | 07:44 | ||
− | | | + | | the third graph is of '''Temperature in degree Celsius'''. |
|- | |- | ||
Line 337: | Line 337: | ||
|- | |- | ||
| 08:19 | | 08:19 | ||
− | |You will find these LEDs next to the '''USB''' connector on the '''SBHS | + | |You will find these LEDs next to the '''USB''' connector on the '''SBHS '''as shown in this image. |
|- | |- | ||
Line 357: | Line 357: | ||
|- | |- | ||
| 08:47 | | 08:47 | ||
− | | Now | + | | Now most of the process that we went through, can be completed by just executing one file. |
|- | |- | ||
Line 365: | Line 365: | ||
|- | |- | ||
| 08:58 | | 08:58 | ||
− | | The steps after launching of '''scilab''', till opening '''xcos''' can be executed using '''start.sce''' file. | + | | The steps after launching of '''scilab''', till opening '''xcos''', can be executed using thr '''start.sce''' file. |
|- | |- |
Latest revision as of 17:55, 23 March 2017
00:01 | Welcome to this Spoken tutorial on “Accessing SBHS through Scilab on Windows”. |
00:07 | SBHS stands for Single Board Heater System. |
00:10 | In this spoken tutorial, we will learn: to set up serial communication between Scilab and SBHS |
00:17 | to perform a Step Test experiment. |
00:20 | For this tutorial, I am using Windows-7 Operating System and Scilab 5.3.3. |
00:28 | You may download Scilab from www.scilab.org. |
00:34 | To install Scilab, watch the "Scilab" spoken tutorial series on: |
00:44 | Before proceeding with this tutorial, you should watch- Introduction to Xcos, Connecting SBHS to computer. |
00:52 | The relevant tutorials for these are available in this series, on the spoken tutorial website. |
00:59 | To begin, we have to download the Scilab Step Test code. So, let us open a web browser. |
01:06 | In the address bar, type: os-hardware.in. Click on the project SBHS and then on the Downloads link. |
01:19 | Download the file available under the section SBHS Local Code and save this file on the Desktop. |
01:29 | Notice that the downloaded file will be in zip format. |
01:34 | Right-click on this file and choose Extract here. |
01:38 | A folder named scilab codes local will be created. |
01:43 | We are now ready to begin our experiment. |
01:47 | Make sure the SBHS is connected to your computer and it is powered ON. |
01:53 | First, we will check the communication port number assigned to the SBHS. |
01:58 | To do this, right-click on My Computer and then click on Properties. |
02:05 | A window will open up. In this window, click on Device Manager. |
02:11 | Please note that the look and feel of Windows 7 is completely different from other Windows versions. |
02:19 | You may also need to vary the steps that I demonstrate here to suit your Windows version. |
02:28 | The device manager will show you a list of hardware devices on your computer. |
02:33 | Locate the Ports (COM & LPT) option. |
02:38 | Here it is! Double-click on this option to open it. |
02:42 | If you have connected RS232 cable, then look for communications Port COM1 . Else, look for USB Serial Port. |
02:52 | For RS232 connection, the port number mostly remains COM1. |
02:59 | For a USB connection, it may change to some other number. |
03:03 | Note down the appropriate COM number; in my case it is COM14. |
03:09 | Now, sometimes the COM port number you get after connecting a USB cable is a two-digit number. |
03:17 | The serial tool box which connects your board and computer can handle only single-digit port number. |
03:24 | Hence, it is necessary to change your COM port number. |
03:28 | Let me show you the procedure to change the COM port number. |
03:31 | Double-click on that particular COM port. |
03:34 | Click on the Port Settings tab and then click on Advanced. |
03:40 | In the COM port number drop-down menu, choose the port number to any other single-digit number. |
03:46 | Windows may show you that all ports are currently in use but in reality, this is only the old status. |
03:55 | Hence you can forcibly use a particular COM port number, if there is no other USB device connected. |
04:03 | Click on OK to apply these settings. |
04:07 | Click on OK to close the Properties window. |
04:11 | Close the Device Manager and the remaining windows. |
04:14 | Now, let us learn how to configure Scilab, to perform a Step Test experiment using SBHS. |
04:23 | Open the Scilab local codes folder that we have saved on the Desktop. |
04:28 | Open the folder Step test. |
04:31 | Locate and double-click on the file ser underscore init dot sce. |
04:37 | This will launch Scilab automatically and will also open the file in Scilab editor. |
04:43 | If it doesn't open the file, click on the File menu, then on Open a file. |
04:50 | Choose the file ser underscore init and click on Open. |
04:57 | Switch to the scilab workspace and execute the following commands. |
05:03 | Type: get d space dot dot slash common underscore files and press the Enter key. |
05:10 | Then type: exec space dot dot slash common underscore files slash loader dot sce and press Enter. |
05:21 | You can see that it gives a message that it has loaded the serial port toolbox. |
05:26 | Switch to the Scilab editor. |
05:28 | In the ser underscore init dot sce file, locate the line which asks for value of variable port2. |
05:36 | Value of port2 variable needs to be replaced with the identified COM port number. |
05:44 | Change the port number to the one you identified or which you have set just a few minutes back. |
05:52 | Make sure this is in single quotes. |
05:55 | Do not make any other changes to the content of this file. |
05:59 | Now, save the file. |
06:01 | On the menu bar, click on the Execute button to execute this file. |
06:06 | On the Scilab workspace you will get a message "COM Port Opened". |
06:12 | However, it is also possible that you get an error message. |
06:16 | Let me explain using slides, how do you handle a typical error. |
06:21 | Let me switch to the slides. |
06:23 | In case a TCL/TK related error is displayed, reconnect the USB cable connected to the SBHS and execute this file again. |
06:33 | Check once if the COM port number has changed. |
06:37 | If it still doesn't work, restart Scilab and repeat the process. |
06:42 | In the Scilab workspace, execute the following commands. |
06:46 | Type: exec space step underscore test dot sci and press Enter. |
06:54 | Then type: xcos space step underscore test dot xcos and press Enter. |
07:03 | This will launch the xcos interface made for step test experiment. |
07:09 | You can change the block parameters by double-clicking on the blocks. |
07:13 | It is recommended that you keep the parameters unchanged for the first time. |
07:18 | In the menubar of the Xcos window, click on the Simulation option, now select the Start option. |
07:27 | After we have executed the Xcos file successfully, a plot window with three graphs will be displayed. |
07:35 | The first graph is of Heater in percentage, |
07:40 | the second graph is of Fan in percentage and |
07:44 | the third graph is of Temperature in degree Celsius. |
07:49 | There are some things to be noted. Let me switch to the slides. |
07:54 | The Fan, Heater and Temperature are displayed on the SBHS display as shown in the image. |
08:01 | Please note that the values shown in the graph should be the same as displayed on the SBHS display. |
08:08 | If this is not the case then it means that Scilab is not communicating with SBHS. |
08:14 | You can also check if the communication LEDs are flashing periodically. |
08:19 | You will find these LEDs next to the USB connector on the SBHS as shown in this image. |
08:26 | Now, this is a real experiment and will take some time to produce results. |
08:30 | I will now pause the recording for some time. |
08:35 | After running the experiment for sufficient time, the final graphs will be as shown here. |
08:41 | We can see that the temperature has responded to the step change in the heat value. |
08:47 | Now most of the process that we went through, can be completed by just executing one file. |
08:53 | Let me show you this file. Switch to the step test folder. |
08:58 | The steps after launching of scilab, till opening xcos, can be executed using thr start.sce file. |
09:07 | Let me switch to slides. |
09:10 | Usage of start dot sce file is recommended only after you get a firm understanding of the process. |
09:17 | This file assumes that the port number provided in the ser underscore init dot sce file is correct. |
09:26 | Now, to stop the experiment, click on the Stop option available in the menu bar of the Xcos window. |
09:35 | After completing the experiment, let us reset the SBHS. |
09:40 | Let me switch to the slides again to illustrate this. |
09:44 | A Reset push button is provided on the SBHS, as shown in the picture. |
09:49 | To reset, press the Reset button for 1 or 2 seconds and then release it. |
09:55 | The reset operation makes Heat 0% and Fan 100%. |
10:00 | However 0 is displayed for both on the LCD. |
10:05 | The data file for this experiment is saved in the Step test folder. |
10:10 | Let me show you this file. |
10:13 | The name of the data file is in the format of a time stamp. |
10:17 | Read the data file name as Year Month Date Hours Minutes Seconds dot txt. |
10:27 | Let me open and show you the content of the data file. |
10:31 | It has values of heat, fan and temperature for every sample. |
10:36 | Hence, this file can be used for analysis purpose. |
10:40 | Now, let us summarise. |
10:42 | In this tutorial, we learnt to set up serial communication between the Scilab and SBHS. |
10:48 | Perform a Step Test experiment. |
10:52 | The video available at the following link summarises the Spoken Tutorial project. Please download and watch it. |
10:58 | The Spoken Tutorial project team conducts workshops and gives certificates to those who pass online tests. |
11:04 | For more details, write to us. |
11:08 | Spoken Tutorial project is funded by NMEICT, MHRD, Government of India. |
11:13 | More information on this mission is available at the link shown here. |
11:17 | Thanks for joining. This is Rupak Rokade from IIT Bombay, signing off. |